@EMedCurious @thepocusatlas Thread c FB pics for atlas #POCUS #IMPOCUS #FOAMed #FOAMus #MedEd @ACEP_EUS @grepmeded @jminardi21 @HeyDrNik @mskultrasound @michaelc0ver @MH_EMultrasound @MetroHealth_EM @PhilipsPOCUS @IMPOCUSFocus @TomJelic @medpedshosp @cianmcdermott @EMBoardBombs
Retained wood piece in volar fingertip-22 days ago. X-rays neg. Diagnosed with felon. Standoff pad in sterile probe sheath used. Removed with alligator forceps.
Retained wood splinter in heel with posterior shadowing seen. Injury happened one day ago. Standoff pad used.
Remote bullet wound--2 years ago. Patient admits to repetitively rubbing it and states it feels irritated/painful so presented to ED.
Broken needle seen posterior to EJ. Startled during police raid while injecting and needle broke off. FB seen short axis with posterior reverberation.
Piece of glass at MCP jt after closed fist injury with window 1 day ago. Note movement of FB with flexion. Glass attached to extensor tendon.
Glass FB seen in near field. Image would have been better if water bath or standoff pad used.
Piece of bamboo broke off in arm 5 days ago. Seen at another facility. Xrays negative. Given Keflex and sent home. Now with increasing pain and early redness. Importance of POCUS for wood/vegetative FBs.
Broken toothpick in sole of foot. Injury happened 5 days ago. Now can't walk. Sag image of FB.
Transverse view of toothpick FB with posterior shadowing noted. Note presence of fluid surrounding the FB.
Broken wood splinter in distal volar pad of finger removed with alligator forceps.